CA Intertest ABP and INTE Abend Error Codes

The CA Intertest Diagnostic Area is printed as one of the User class storage areas in the INTE abend dump. It contains the error code as the first two characters of the message XX INTE ABEND..., which can be found in the beginning of the area. The codes and their messages (as documeted in Appendix C of the CA Intertest User Guide) are listed below. These 2 character hexadecimal codes appear in the Inquiry Report, which may be obtained by pressing PF3 from the Breakpoint Display or by entering: CNTL=INQ.

Code Description
01 Assembler only: and EX machine instruction issued upon an EX instruction
02 An invalid machine instruction code. Note: No override by OVR option.
03 This machine instruction not permitted under CICS, for example, an SVC.
04 A priviledged machine instruction, illegal under CICS.
05 An Operating System GETMAIN request, as opposed to a CICS GETMAIN.
06 The storage area about to be affected is, entirely or in part, outside of the
storage that is legally available to this CICS application.
07 The storage area about to be affected resides outside of the CICS region.
08 The named program module cannot be found in the program table (PPT),
or its PPT entry is disabled, or it is unavailable to this CICS application.
09 The program module about to be DELETEd already has a zero current use count.
0A The Transient Data or Temporary Storage area is incorrectly specified.
0B This Terminal Control request incorrectly specifies the TIOA address.
0C The storage area specified for this CICS request does not belong to this
task or is not a CICS storage area.
0D CA Intertest logic error. Please call CA Technical Support for assistance.
0E This FREEMAIN request is illegal or specifies a wrong storage area address.
0F With this task about to terminate, one or more RELOAD=YES program modules
still do not have their main storage areas FREEMAINed.
10 Possible incorrect length of a Temporary Storage or Transient Data record.
11 A wild branch or direct machine instruction branch outside of the program module
was detected. If not a mistake, apply the FOL option and continue.
12 Macro level coding only; this CICS macro specifies incorrect storage area.
13 A GETMAIN request with FLENGTH for more than 65504 bytes may be issued only
when the program is in AMODE=31.
14 An attempt to modify this load module which is considered reentrant, either
explicitly (RNT=ON) or as PL/I or COBOL II.
16 A GETMAIN for 0 bytes of storage has been detected.
17 Macro Level coding only; incorrect length field in a variable-length record.
18 Macro Level coding only; the DFHFC macro does not specify an FWA.
19 Macro Level coding only; the DFHFC macro does ot specify the storage area of CLASS=FILE.
21 CA Intertest ordered to continue a task from a breakpoint at an incorrect location.
23 The total number of CICS requests this program issued while monitored in this task
exceeded the value specified in the MXR option.
24 The total size of main storage this task is using has just exceeded the value specified
in the MXS option.
25 CICS abend intercepted, but not immediately after the last CICS request (either macro or command)
or another outside CALL recognized by CA Intertest.
26 CICS abend intercepted while a CICS macro was in progress.
27 CICS abend intercepted while an EXEC CICS command in progress.
28 CICS abend intercepted while a CALL outside the program, such as a Database request, recognized
by CA Intertest, was in progress.
29 EXEC CICS RETURN with TRANSID issued from other than the task's top logical level.
2C An abend occurred while processing an IN25UEXI routine.
2D A program check occurred in IN25PGM2.
34 A protection exception program check caused an ASRA abend intercept.
35 An addressing exception program check caused an ASRA abend intercept.
36 A specification exception program check caused an ASRA abend intercept.
37 A data exception (invalid packed numeric data format) caused an ASRA abend intercept.
38 A fixed point overflow program check caused an ASRA abend intercept.
39 A fixed point divide program check caused an ASRA abend intercept.
3A A decimal overflow program check caused an ASRA abend intercept.
3B A decimal divide program check caused an ASRA abend intercept.
3C An exponent overflow program check caused an ASRA abend intercept.
3D An exponent underflow program check caused an ASRA abend intercept.
3E A 'signifigance' program check caused an ASRA abend intercept.
3F A floating point divide program check caused an ASRA abend intercept.
CC The storage area about to be affected by this EXEC CICS command resides, all or in part,
outside of the CICS main storage legally available to this application program.
The area could have been specified as INTO () or SET () or one of the LENGTHs.